CT-IG-MTAS192-2008-v1_8.doc
Comtest Networks
MTAS-192
June 2006 Installation Guide
49
Table 22: RJ-21 Pinouts
DSL (Front) LINE/FACILITY (Rear) POTS/EQUIPMENT (Rear)
Port/Pair
Number
Tip Ring Tip Ring Tip Ring
1 26 1 26 1 26 1
2 27 2 27 2 27 2
3 28 3 28 3 28 3
4 29 4 29 4 29 4
5 30 5 30 5 30 5
6 31 6 31 6 31 6
7 32 7 32 7 32 7
8 33 8 33 8 33 8
9 34 9 34 9 34
9
10 35 10 35 10 35
10
11 36 11 36 11 36
11
12 37 12 37 12 37
12
13 38 13 38 13 38
13
14 39 14 39 14 39
14
15 40 15 40 15 40
15
16 41 16 41 16 41
16
17 42 17 42 17 42
17
18 43 18 43 18 43
18
19 44 19 44 19 44
19
20 45 20 45 20 45
20
21 46 21 46 21 46
21
22 47 22 47 22 47
22
23 48 23 48 23 48
23
24 49 24 49 24
49 24
Alarm Cabling
Two female RJ11 jacks on the MTAS backplane correspond to MAJOR and MINOR
audible and visible alarms (normally open contacts).
Table 23: Alarm Cable Pinouts
MAJOR MINOR
Pin No. Alarm Pin No. Alarm
1 1
2
Major Visible Alarm
2
Minor Visible Alarm
3 3
4
Major Audible Alarm
4
Minor Audible Alarm
# # #
Comentarios a estos manuales